{"id":11063,"date":"2017-09-01T20:05:05","date_gmt":"2017-09-01T20:05:05","guid":{"rendered":"https:\/\/insulation.org\/io\/?post_type=articles&#038;p=11063"},"modified":"2017-10-03T20:06:59","modified_gmt":"2017-10-03T20:06:59","slug":"energy-efficiency-in-insulation-systems","status":"publish","type":"articles","link":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/","title":{"rendered":"Energy Efficiency in Insulation Systems"},"content":{"rendered":"<p>Let\u2019s look into the industrial and commercial insulation realm. The goal of insulation is to keep the heat in the system as long as possible\u2014or at least until it\u2019s delivered to its useful destination. Insulation\u2019s effectiveness is tied in good portion to its efficiency, which requires that all material be installed correctly. Once it is in place, the efficiency is tied to proper maintenance, managing product aging, and remediation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-11082\" src=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg\" alt=\"\" width=\"234\" height=\"300\" srcset=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg 234w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-768x985.jpg 768w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-798x1024.jpg 798w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2.jpg 830w\" sizes=\"auto, (max-width: 234px) 100vw, 234px\" \/><\/p>\n<p>One of the tools that can address both sides of these issues is a thermal camera. Imaging insulation for effective and proper installation eliminates efficiency issues up front. Correspondingly, thermal imaging an existing system for wear or damage can help managers make effective remediation or replacement decisions. Our discussion will revolve around both of these processes and the knowledge needed to effectively utilize a thermal camera in these 2 application scenarios.<\/p>\n<p>To measure installation effectiveness, you would have the mechanical contractors put the insulation in place in the proscribed manner. Field conditions sometimes bring about unintentional and maybe intentional inefficiencies\u2014if you have not enlisted an experienced contractor\u2014when installing insulation. It can be difficult and expensive to fix installation issues after the fact, which is why it\u2019s so important to hire skilled mechanical insulation contractors.<\/p>\n<p>As an example, consider Figure 1. The piping has a cover on it and would not look any different to the naked eye, but the thermal camera demonstrates that the insulation at the corner is less efficient than the straight sections. Insulating around bends requires special attention to prevent this type of heat loss. This type of inefficiency costs the building owners in 2 ways: first because the system has to work harder to make up for the heat loss, and also in the cooling to remove the excess heat from the surrounding building environment. While the camera easily illustrates the issue, the solution may not be so simple.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11079\" src=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_01-300x254.jpg\" alt=\"\" width=\"400\" height=\"339\" srcset=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_01-300x254.jpg 300w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_01-768x651.jpg 768w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_01-1024x868.jpg 1024w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_01.jpg 1038w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Another common problem area is support saddles. They attach directly to the process piping and the energy conducts into the saddle and the hanger. As the infrared image in Figure 2 shows, the situation has a couple of issues. One is a safety issue, in that the hanger and support are very hot and present burn potential to any unsuspecting worker. The other concern is the loss of energy from this saddle\u2014how much energy can be lost from this type of issue?<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11080\" src=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_02-300x252.jpg\" alt=\"\" width=\"400\" height=\"336\" srcset=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_02-300x252.jpg 300w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_02-768x645.jpg 768w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_02-1024x861.jpg 1024w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_02.jpg 1040w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Assuming this is a approximately a half square foot of area, a quick calculation shows that this is radiating and convecting about 80 watts\/hr or 273 Btu\/hr. That would mean in one day, this one saddle is putting 6500 Btu\/hr into this space. As an example, let\u2019s say there are 50 saddles on this pipe run\u2014that would make the loss equal approximately 325,000 Btu per day (plus the cooling to remove it at 25 tons.) Assuming the cost of gas energy is around $1.10 per therm, the energy savings from fixing this issue would be more than $1,500 per year.<\/p>\n<p>In the insulation industry, it is typical to run heat-loss calculations on a pipe under different insulation types to find the right cost to efficiency return on investment (ROI). Thermal imaging can be a valuable tool in this process to find damage or inefficiencies that cannot be seen by the naked eye, and help determine if an immediate repair is needed to prevent any issues, or if a future remediation would be more cost effective.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11081\" src=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_03-300x223.jpg\" alt=\"\" width=\"400\" height=\"297\" srcset=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_03-300x223.jpg 300w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_03-768x570.jpg 768w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_03-1024x760.jpg 1024w, https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/IO170902_03.jpg 1056w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Taking an obviously damaged section, see Figure 3, it is possible to calculate the loss and determine the payback for repair. Assuming a 2\u201d pipe with a surface temperature of 483\u00b0F and ambient temperature of 94\u00b0F, the bare pipe heat loss is about 1478 Btu\/hr\/ft. With 2\u201d of mineral wool insulation, the heat loss drops to about 74 BTU\/hr\/ft, giving a net heat loss of 1404 Btu\/hr\/ft. For a one foot length, this gives a net heat loss of about 12.3 MBtu annually. The industrial price of natural gas is about $4.02\/mcf. At an energy efficiency of 0.40, this gives a cost of about $10\/Btu, resulting in an annual cost of about $123\/ft. Cooling is about $10\/MBtu, so if the environment needed to be cooled, double the cost to $246\/ft. This information can be factored into a maintenance plan and decisions for repair can be made.<\/p>\n<p>As demonstrated above, thermal cameras can find and identify the inefficiencies in a system. Taking measurements and various parameters to extract meaningful information can assist in quantifying these issues into meaningful cost and repair numbers that can help facility owners make repair and maintenance decisions.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Copyright Statement<\/strong><\/p>\n<p>This article was published in the September 2017 issue of Insulation Outlook magazine. Copyright\u00a0\u00a9 2017 National Insulation Association. All rights reserved. The contents of this website and Insulation Outlook magazine may not be reproduced in any means, in whole or in part, without the prior written permission of the publisher and NIA. Any unauthorized\u00a0duplication is strictly prohibited and would violate NIA\u2019s copyright and may violate other copyright agreements that NIA has with authors and partners. Contact <a href=\"mailto&#58;&#112;&#117;&#98;&#108;&#105;&#115;&#x68;&#x65;&#x72;&#x40;&#x69;&#x6e;&#x73;&#x75;&#x6c;&#x61;&#x74;&#x69;on&#46;org\">&#112;u&#x62;l&#x69;&#115;&#x68;&#101;&#x72;&#64;i&#x6e;s&#x75;&#108;&#x61;&#116;&#x69;&#111;&#x6e;&#46;o&#x72;g<\/a> to reprint or reproduce this content.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Let\u2019s look into the industrial and commercial insulation realm. The goal of insulation is to keep the heat in the system as long as possible\u2014or at least until it\u2019s delivered to its useful destination. Insulation\u2019s effectiveness is tied in good portion to its efficiency, which requires that all material be installed correctly. Once it is<\/p>\n","protected":false},"author":[321],"featured_media":0,"template":"","categories":[33,290,28,405],"class_list":["post-11063","articles","type-articles","status-publish","hentry","category-high-temperature-systems","category-emissivity","category-energy-savings","category-september-2017","author-jay-bowen"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.0 (Yoast SEO v24.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Energy Efficiency in Insulation Systems - Insulation Outlook Magazine<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Energy Efficiency in Insulation Systems\" \/>\n<meta property=\"og:description\" content=\"Let\u2019s look into the industrial and commercial insulation realm. The goal of insulation is to keep the heat in the system as long as possible\u2014or at least until it\u2019s delivered to its useful destination. Insulation\u2019s effectiveness is tied in good portion to its efficiency, which requires that all material be installed correctly. Once it is\" \/>\n<meta property=\"og:url\" content=\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"Insulation Outlook Magazine\" \/>\n<meta property=\"article:modified_time\" content=\"2017-10-03T20:06:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/\",\"url\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/\",\"name\":\"Energy Efficiency in Insulation Systems - Insulation Outlook Magazine\",\"isPartOf\":{\"@id\":\"https:\/\/insulation.org\/io\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg\",\"datePublished\":\"2017-09-01T20:05:05+00:00\",\"dateModified\":\"2017-10-03T20:06:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage\",\"url\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2.jpg\",\"contentUrl\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2.jpg\",\"width\":830,\"height\":1065},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/insulation.org\/io\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Energy Efficiency in Insulation Systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/insulation.org\/io\/#website\",\"url\":\"https:\/\/insulation.org\/io\/\",\"name\":\"Insulation Outlook Magazine\",\"description\":\"The only global magazine dedicated to insulation.\",\"publisher\":{\"@id\":\"https:\/\/insulation.org\/io\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/insulation.org\/io\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/insulation.org\/io\/#organization\",\"name\":\"National Insulation Association\",\"url\":\"https:\/\/insulation.org\/io\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"contentUrl\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"width\":229,\"height\":90,\"caption\":\"National Insulation Association\"},\"image\":{\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Energy Efficiency in Insulation Systems - Insulation Outlook Magazine","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/","og_locale":"en_US","og_type":"article","og_title":"Energy Efficiency in Insulation Systems","og_description":"Let\u2019s look into the industrial and commercial insulation realm. The goal of insulation is to keep the heat in the system as long as possible\u2014or at least until it\u2019s delivered to its useful destination. Insulation\u2019s effectiveness is tied in good portion to its efficiency, which requires that all material be installed correctly. Once it is","og_url":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/","og_site_name":"Insulation Outlook Magazine","article_modified_time":"2017-10-03T20:06:59+00:00","og_image":[{"url":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/","url":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/","name":"Energy Efficiency in Insulation Systems - Insulation Outlook Magazine","isPartOf":{"@id":"https:\/\/insulation.org\/io\/#website"},"primaryImageOfPage":{"@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage"},"image":{"@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2-234x300.jpg","datePublished":"2017-09-01T20:05:05+00:00","dateModified":"2017-10-03T20:06:59+00:00","breadcrumb":{"@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#primaryimage","url":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2.jpg","contentUrl":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2017\/10\/Opening-Art-2.jpg","width":830,"height":1065},{"@type":"BreadcrumbList","@id":"https:\/\/insulation.org\/io\/articles\/energy-efficiency-in-insulation-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/insulation.org\/io\/"},{"@type":"ListItem","position":2,"name":"Energy Efficiency in Insulation Systems"}]},{"@type":"WebSite","@id":"https:\/\/insulation.org\/io\/#website","url":"https:\/\/insulation.org\/io\/","name":"Insulation Outlook Magazine","description":"The only global magazine dedicated to insulation.","publisher":{"@id":"https:\/\/insulation.org\/io\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/insulation.org\/io\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/insulation.org\/io\/#organization","name":"National Insulation Association","url":"https:\/\/insulation.org\/io\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/","url":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","contentUrl":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","width":229,"height":90,"caption":"National Insulation Association"},"image":{"@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles\/11063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/types\/articles"}],"wp:attachment":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/media?parent=11063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/categories?post=11063"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/author?post=11063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}