{"id":7175,"date":"2007-11-01T00:00:00","date_gmt":"2007-11-01T00:00:00","guid":{"rendered":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/"},"modified":"2007-11-01T00:00:00","modified_gmt":"2007-11-01T00:00:00","slug":"ask-the-expert-2","status":"publish","type":"articles","link":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/","title":{"rendered":"Ask the Expert"},"content":{"rendered":"<p>This recurring <a href=\"http:\/\/www.insulationoutlook.org\/io\/\"><em>Insulation Outlook<\/em><\/a> column features Ronald L. &ldquo;Ron&rdquo; King, a past president of the National  Insulation Association (NIA), the World Insulation and Acoustic Organization  (WIACO), and the Southwest Insulation Contractors Association (SWICA). King is  a 40-plus-year veteran of the commercial and industrial insulation industry and  is currently a consultant and adviser to NIA on a variety of outreach and  educational initiatives. Contact him at 757-229-7443 or <a href=\"&#x6d;&#97;&#105;&#x6c;&#x74;&#111;&#58;&#x72;&#x6f;&#110;&#107;&#x69;&#x6e;&#103;&#82;&#x4c;&#x4b;&#64;&#97;&#x6f;&#x6c;&#46;&#99;&#x6f;&#x6d;\">&#x72;&#x6f;&#x6e;&#x6b;&#x69;&#x6e;&#x67;&#x52;&#x4c;&#x4b;&#x40;&#x61;&#x6f;&#x6c;&#x2e;&#x63;&#x6f;&#x6d;<\/a>.<\/p>\n<p><strong>Q: With the cost of a  barrel of oil and many other energy sources at record-high levels, why isn&rsquo;t  insulation at the top of the list of energy conservation initiatives?<\/strong><\/p>\n<p><strong>A:<\/strong> Mechanical insulation  is a relatively simple energy conservation initiative that can provide an  annual return on investment (ROI) of more than 100 percent (and, in some cases,  more than 200 percent). However, the technology is still underutilized and  under-valued. Why? There are two primary reasons: knowledge and competing  initiatives.<\/p>\n<p>The ultimate decision makers (facility managers, chief  financial officers, budget directors, etc.) do not appreciate the ROI  opportunities with upgrading and maintaining insulation. They take the initial  installation for granted and assume it is being maintained within allocated  budget dollars. Operational and maintenance personnel understand the  opportunity, but the decision makers are continually cutting or deferring  maintenance dollars and do not consider insulation an energy conservation  initiative. <\/p>\n<p>Combine the lack of knowledge with the hundreds of other  energy conservation initiatives for which the industry is competing for capital  and maintenance dollars, and you can visualize the problem. <\/p>\n<p>The mechanical insulation industry is competing with  lighting, steam traps, controls, motors, solar power, and many types of  equipment, not to mention various engineering initiatives. Competition within  the industry is minor in comparison to external competition, yet the industry  is spending relatively few marketing dollars to combat those forces. Therefore,  insulation is not obtaining its fair share of capital and maintenance dollars  in the energy conservation field.<\/p>\n<p>There is not a single answer to this question. But  education, education, and more education is the best place to start.<\/p>\n<p><strong>Q: It has been  reported that a substantial percentage of installed mechanical insulation is  missing or damaged. Given the consequences of such damage, why is insulation  maintenance not a priority?<\/strong><\/p>\n<p><strong>A:<\/strong> It has been  estimated that 10 to 30 percent of all mechanical insulation is missing or  damaged. This is a realistic estimate for most U.S. facilities. The Department  of Energy&rsquo;s (DOE&rsquo;s) Save Energy Now (SEN) program has also confirmed that the  problem of missing or damaged insulation is more widespread than many would  like to acknowledge.<\/p>\n<p>Most facilities have annual maintenance budgets that cover a  host of activities, including insulation. As discussed in the previous answer,  insulation must compete for those dollars. Many look at it this way: The plant  is producing a quality product at a profit, so the insulation must be  performing as expected. They do not look at insulation as a means to reduce  costs by conserving energy, reducing greenhouse gas emissions, improving  productivity, improving employee safety, reducing potential corrosion under  insulation, reducing condensation, and reducing the potential of mold  development. They also fail to acknowledge how maintenance dollars can provide  a substantial ROI. Insulation is taken for granted and not considered a  priority. Again, knowledge and competing initiatives are at the core of this  issue.<\/p>\n<p><strong>Q: What is the best  resource for an engineer, architect, or facility manager to use to obtain  information on mechanical insulation?<\/strong><\/p>\n<p><strong>A:<\/strong> There are many  excellent resource documents available from the American Society of Heating,  Refrigerating and Air-Conditioning Engineers (ASHRAE), Masterspec, Midwest  Insulation Contractors Association (MICA), Process Industry Practices (PIP),  and the National Insulation Association (NIA). All of these documents make one  general assumption&mdash;the  reader has general knowledge of insulation materials and systems. However, this  assumption is not always correct.<\/p>\n<p>NIA has several great training programs that can provide  knowledge and information about how to use the various industry resources.<\/p>\n<p>Product manufacturers are also a great resource. Their story  is normally biased to their products and\/or systems; though stretched thin,  they are a good resource. Insulation contractors, distributors, and fabricators  are also an excellent resource, but are also <br \/>\n  stretched thin because providing education and developing  specifications are really not their roles.<\/p>\n<p>Academia, engineering, and architectural courses are  minimally addressing mechanical insulation in their curricula, at best. The  bottom line is that the knowledge base of mechanical insulation at the  engineering, architectural, and facility owner level has eroded, and those  users are turning to multiple sources for information. Unfortunately, due to  lack of knowledge they sometimes obtain insufficient information to make the  correct decision.<\/p>\n<p>In January 2008, the National Institute of Building Sciences  (NIBS) is launching a Web-based vertical portal entitled the <em>Mechanical Insulation Design Guide (MIDG).<\/em> This will be a  giant step forward in providing a single resource for the novice or the  informed individual on the various mechanical insulation products and systems;  insulation system design considerations; installation; and design data. It will  also provide links to the various resources previously mentioned.<\/p>\n<p><em>Readers are encouraged  to submit their own insulation questions to industry experts by e-mailing <\/em><a href=\"&#x6d;&#x61;&#105;&#108;t&#x6f;&#x3a;&#x61;&#115;kt&#x68;&#x65;&#101;&#120;p&#x65;&#x72;&#x74;&#64;in&#x73;&#x75;&#108;&#97;t&#x69;&#x6f;&#x6e;&#46;or&#x67;\">&#97;&#x73;k&#116;&#x68;e&#101;&#x78;p&#x65;&#x72;&#116;&#x40;i&#110;&#x73;u&#108;&#x61;t&#x69;&#x6f;&#110;&#x2e;&#x6f;&#114;&#x67;<\/a><em>. Questions can be on any insulation topic.  Future topics will include building design trends, boilers, insulation  maintenance, acoustics, bril, and refractory.<\/em><\/p>\n<p><strong>Disclaimer:<\/strong> Unless specifically noted in the beginning of the article, the content,  calculations, and opinions expressed by the author, as in any article in <a href=\"http:\/\/www.insulationoutlook.org\/io\/\"><em>Insulation Outlook<\/em><\/a>, are those of the author, are based upon  the limited information provided to the author in the question asked, and do  not necessarily reflect the views of the National Insulation Association (NIA).  The appearance of an article, advertisements, and\/or product or service  information in <a href=\"http:\/\/www.insulationoutlook.org\/io\/\"><em>Insulation Outlook<\/em><\/a> does not constitute  an endorsement of such products or services by NIA.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This recurring Insulation Outlook column features Ronald L. &ldquo;Ron&rdquo; King, a past president of the National Insulation Association (NIA), the World Insulation and Acoustic Organization (WIACO), and the Southwest Insulation Contractors Association (SWICA). King is a 40-plus-year veteran of the commercial and industrial insulation industry and is currently a consultant and adviser to NIA on<\/p>\n","protected":false},"author":[308],"featured_media":0,"template":"","categories":[294,21,297,302,28],"class_list":["post-7175","articles","type-articles","status-publish","hentry","category-training","category-business-managment","category-basic-understanding","category-economy","category-energy-savings","author-ronald-l-king"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.0 (Yoast SEO v24.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Ask the Expert - Insulation Outlook Magazine<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ask the Expert\" \/>\n<meta property=\"og:description\" content=\"This recurring Insulation Outlook column features Ronald L. &ldquo;Ron&rdquo; King, a past president of the National Insulation Association (NIA), the World Insulation and Acoustic Organization (WIACO), and the Southwest Insulation Contractors Association (SWICA). King is a 40-plus-year veteran of the commercial and industrial insulation industry and is currently a consultant and adviser to NIA on\" \/>\n<meta property=\"og:url\" content=\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Insulation Outlook Magazine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/\",\"url\":\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/\",\"name\":\"Ask the Expert - Insulation Outlook Magazine\",\"isPartOf\":{\"@id\":\"https:\/\/insulation.org\/io\/#website\"},\"datePublished\":\"2007-11-01T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/insulation.org\/io\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ask the Expert\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/insulation.org\/io\/#website\",\"url\":\"https:\/\/insulation.org\/io\/\",\"name\":\"Insulation Outlook Magazine\",\"description\":\"The only global magazine dedicated to insulation.\",\"publisher\":{\"@id\":\"https:\/\/insulation.org\/io\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/insulation.org\/io\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/insulation.org\/io\/#organization\",\"name\":\"National Insulation Association\",\"url\":\"https:\/\/insulation.org\/io\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"contentUrl\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"width\":229,\"height\":90,\"caption\":\"National Insulation Association\"},\"image\":{\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ask the Expert - Insulation Outlook Magazine","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/","og_locale":"en_US","og_type":"article","og_title":"Ask the Expert","og_description":"This recurring Insulation Outlook column features Ronald L. &ldquo;Ron&rdquo; King, a past president of the National Insulation Association (NIA), the World Insulation and Acoustic Organization (WIACO), and the Southwest Insulation Contractors Association (SWICA). King is a 40-plus-year veteran of the commercial and industrial insulation industry and is currently a consultant and adviser to NIA on","og_url":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/","og_site_name":"Insulation Outlook Magazine","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/","url":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/","name":"Ask the Expert - Insulation Outlook Magazine","isPartOf":{"@id":"https:\/\/insulation.org\/io\/#website"},"datePublished":"2007-11-01T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/insulation.org\/io\/articles\/ask-the-expert-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/insulation.org\/io\/"},{"@type":"ListItem","position":2,"name":"Ask the Expert"}]},{"@type":"WebSite","@id":"https:\/\/insulation.org\/io\/#website","url":"https:\/\/insulation.org\/io\/","name":"Insulation Outlook Magazine","description":"The only global magazine dedicated to insulation.","publisher":{"@id":"https:\/\/insulation.org\/io\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/insulation.org\/io\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/insulation.org\/io\/#organization","name":"National Insulation Association","url":"https:\/\/insulation.org\/io\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/","url":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","contentUrl":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","width":229,"height":90,"caption":"National Insulation Association"},"image":{"@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles\/7175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/types\/articles"}],"wp:attachment":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/media?parent=7175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/categories?post=7175"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/author?post=7175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}