{"id":7257,"date":"2006-06-01T00:00:00","date_gmt":"2006-06-01T00:00:00","guid":{"rendered":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/"},"modified":"2006-06-01T00:00:00","modified_gmt":"2006-06-01T00:00:00","slug":"changes-in-codes-aiming-to-save-lives","status":"publish","type":"articles","link":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/","title":{"rendered":"Changes in Codes&mdash;Aiming to Save Lives"},"content":{"rendered":"<p>There&rsquo;s an old expression: Good  enough just isn&rsquo;t good enough. For writers of the standard building codes, that  expression is pretty accurate. Each time the code is reviewed, it is a sure bet  that there will be changes. Some of those changes lighten up restrictions to  take into account significant technology improvements. More often, restrictions  become tighter in an attempt to eliminate recognized potential errors in system  design or installation that can cost the lives of building occupants and\/or  first responders.<\/p>\n<p>Certainly, the latter is the case  regarding changes in the code section concerning perimeter fire protection in  mid- and high-rise buildings. While there was only one change in this section,  allowing the perimeter void installation to conform to the new ASTM E2307 test  method, that single change had quite an impact.<\/p>\n<p>Two code references are of  particular importance in perimeter fire containment. It is worth digging up a copy  of the International Building Code (IBC) code book&mdash;old or new version&mdash;to  highlight the important sections.<\/p>\n<p>The first code reference is in  section 704.9. In this section, the code writers try to protect against the  vertical spread of fire on the exterior of a building. The code requires  three-foot or greater vertical spandrel girders, or at least 30&rdquo; horizontal  protrusions such as balconies, on buildings more than three stories high when  not equipped with an automatic sprinkler system.<\/p>\n<p>Next, consider Section 713.4,  Exterior Curtain Wall\/Floor Intersection, which focuses on maintaining the  integrity of the floor slab. This section requires filling the void (safing  area) between the floor slab and the exterior curtain wall, which must be done  to protect against the interior  spread of fire between the floor slab edge and the curtain wall. The void is to  be sealed with an approved system or materials to prevent passage of flame and  hot gasses, and must maintain the same fire resistance rating as the floor  assembly. A change in this section of the code adds that the installed material  can either meet the requirements of ASTM E119 or it can be a system &ldquo;installed  in accordance with ASTM E2307,&rdquo; a recently adopted two-story fire test.<\/p>\n<p>Now, as is so often the case, an  important caveat emerges from practical application of the code.<\/p>\n<p>Section 704.9, Vertical  Separation of Openings, provides that separating devices such as spandrel  girders or exterior protrusions are not required for buildings that are three  stories or fewer in height, or that are equipped throughout with automatic  sprinkler systems.<\/p>\n<p>On the surface, Section 704.9  language eliminates the need for spandrel panels in sprinkled buildings.  However, the code language does not eliminate Section 713.4. Taken in  connection with Section 713.4, it is clear that the assembly of the spandrel  area along with the perimeter void must be protected and must remain in place  to provide at least the same fire-rated performance as the floor slab.<\/p>\n<p>Without a tested assembly to  ensure that the curtain wall structure will not be compromised in event of a  fire, there can be no assurance that the protection in the perimeter void will  remain in place. If the curtain wall gives way, perimeter void protection  fails.<\/p>\n<p>This has already been proved in a  testing environment. Mineral wool safing was installed between a floor slab and  an unprotected glass curtain wall. Just five minutes into the test, the curtain  wall glass failed, allowing the safing insulation to dislodge.1 In other words,  even though the void between the curtain wall and the floor slab edge was  filled to meet the intent of the code requirement, the assembly failed to meet  the fire-rated expectations of the building codes.<\/p>\n<p>Breach of a floor barrier in a  five-minute span calls into question the exceptions stated in the current code  under Section 704.9. Is it really reasonable to expect fire department response  time to be better just because a building is less than three stories tall?<\/p>\n<p>Prudent readers of the code will  recognize that properly protected spandrel panels at the curtain wall\/floor  slab intersection are essential for truly meeting code requirements. Assemblies  tested to ASTM E2307 meet those requirements. There are no exceptions.<\/p>\n<h5><em>References:<\/em><\/h5>\n<p><em>American Society for Testing Materials, &ldquo;ASTM E2307-04<\/em>&mdash;<em>Standard Test Method for Determining Fire  Resistance of Perimeter Fire Barrier Systems Using the Intermediate-Scale  Multi-story Test Apparatus,&rdquo; Volume 04.07, Building Seals and Sealants, Fire  Standards: Dimension Stone, 2005. International Code Council, International  Building Code, Section 704.9, &ldquo;Vertical Separation of Openings&rdquo; and Section  713.4 &ldquo;Exterior Curtain Wall\/Floor Intersection,&rdquo; IBC 2006. Loss Prevention  Council, &ldquo;Fire Spread in Multi-Storey Buildings with Glazed Curtain Wall  Facades,&rdquo; LPR 11:1999. Shriver, James C., and Cordts, Brandon, &ldquo;Clarifying  Curtain Wall Firestop Standards,&rdquo; Technical White Paper, 2001. <a href=\"http:\/\/www.fcia.org\">www.fcia.org<\/a>, Firestop Contractors International  Association website, 2006. <a href=\"http:\/\/www.firestop.org\">www.firestop.org<\/a>, International Firestop Council website, 2006. <a href=\"http:\/\/www.afscc.org\">www.afscc.org<\/a>, Alliance for Fire and Smoke Containment  and Control website, 2006.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>There&rsquo;s an old expression: Good enough just isn&rsquo;t good enough. For writers of the standard building codes, that expression is pretty accurate. Each time the code is reviewed, it is a sure bet that there will be changes. Some of those changes lighten up restrictions to take into account significant technology improvements. More often, restrictions<\/p>\n","protected":false},"author":[230],"featured_media":0,"template":"","categories":[34,301,32],"class_list":["post-7257","articles","type-articles","status-publish","hentry","category-industrial","category-design","category-health-and-safety","author-james-c-shriver"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.0 (Yoast SEO v24.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Changes in Codes&mdash;Aiming to Save Lives - Insulation Outlook Magazine<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Changes in Codes&mdash;Aiming to Save Lives\" \/>\n<meta property=\"og:description\" content=\"There&rsquo;s an old expression: Good enough just isn&rsquo;t good enough. For writers of the standard building codes, that expression is pretty accurate. Each time the code is reviewed, it is a sure bet that there will be changes. Some of those changes lighten up restrictions to take into account significant technology improvements. More often, restrictions\" \/>\n<meta property=\"og:url\" content=\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/\" \/>\n<meta property=\"og:site_name\" content=\"Insulation Outlook Magazine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/\",\"url\":\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/\",\"name\":\"Changes in Codes&mdash;Aiming to Save Lives - Insulation Outlook Magazine\",\"isPartOf\":{\"@id\":\"https:\/\/insulation.org\/io\/#website\"},\"datePublished\":\"2006-06-01T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/insulation.org\/io\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Changes in Codes&mdash;Aiming to Save Lives\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/insulation.org\/io\/#website\",\"url\":\"https:\/\/insulation.org\/io\/\",\"name\":\"Insulation Outlook Magazine\",\"description\":\"The only global magazine dedicated to insulation.\",\"publisher\":{\"@id\":\"https:\/\/insulation.org\/io\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/insulation.org\/io\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/insulation.org\/io\/#organization\",\"name\":\"National Insulation Association\",\"url\":\"https:\/\/insulation.org\/io\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"contentUrl\":\"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png\",\"width\":229,\"height\":90,\"caption\":\"National Insulation Association\"},\"image\":{\"@id\":\"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Changes in Codes&mdash;Aiming to Save Lives - Insulation Outlook Magazine","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/","og_locale":"en_US","og_type":"article","og_title":"Changes in Codes&mdash;Aiming to Save Lives","og_description":"There&rsquo;s an old expression: Good enough just isn&rsquo;t good enough. For writers of the standard building codes, that expression is pretty accurate. Each time the code is reviewed, it is a sure bet that there will be changes. Some of those changes lighten up restrictions to take into account significant technology improvements. More often, restrictions","og_url":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/","og_site_name":"Insulation Outlook Magazine","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/","url":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/","name":"Changes in Codes&mdash;Aiming to Save Lives - Insulation Outlook Magazine","isPartOf":{"@id":"https:\/\/insulation.org\/io\/#website"},"datePublished":"2006-06-01T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/insulation.org\/io\/articles\/changes-in-codes-aiming-to-save-lives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/insulation.org\/io\/"},{"@type":"ListItem","position":2,"name":"Changes in Codes&mdash;Aiming to Save Lives"}]},{"@type":"WebSite","@id":"https:\/\/insulation.org\/io\/#website","url":"https:\/\/insulation.org\/io\/","name":"Insulation Outlook Magazine","description":"The only global magazine dedicated to insulation.","publisher":{"@id":"https:\/\/insulation.org\/io\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/insulation.org\/io\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/insulation.org\/io\/#organization","name":"National Insulation Association","url":"https:\/\/insulation.org\/io\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/","url":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","contentUrl":"https:\/\/insulation.org\/io\/wp-content\/uploads\/sites\/3\/2016\/10\/insulation-outlook-logo.png","width":229,"height":90,"caption":"National Insulation Association"},"image":{"@id":"https:\/\/insulation.org\/io\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles\/7257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/types\/articles"}],"wp:attachment":[{"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/media?parent=7257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/categories?post=7257"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/insulation.org\/io\/wp-json\/wp\/v2\/author?post=7257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}